Journeyman Electrician Practice Test: Important Question to Prepare
Preparing for the journeyman electrician practice test can feel stressful. The exam covers electrical theory, wiring methods, load calculations, NEC rules, and safety requirements. A strong study plan helps you pass with confidence. Understanding how the test works and practicing realistic questions will sharpen your skills. This guide explains everything you need to know and gives you a full practice test so you can check your progress. Know more about How to Get Electrical Certification in USA & Transfer It to Europe.
Studying smart is the key. Break the preparation into small steps. Read the NEC. Review formulas. Practice calculations. Try sample questions often. This improves accuracy and reduces guessing. The journeyman electrician practice test is designed to evaluate real-world electrical knowledge. You must show that you can work safely and follow code.

Table of Contents
Hands-on experience helps you remember concepts faster. Still, written questions can be tricky. Some test items look simple but hide small details. Others require reading NEC tables correctly. Practicing these question styles builds confidence. Use the practice test below to measure your strengths.
Know more about Electrical Safety Officer Certification in USA: Cost, Duration & Job Scope
Another important part is managing your exam time. Most test-takers rush through calculation questions. A better strategy is to answer code-based questions first. Then return to calculations. This keeps your pace steady. A structured journeyman electrician practice test like the one below helps you practice this timing approach.
Before you begin the practice test, review key areas:
Core Topics Found in the Journeyman Exam
Electrical Theory Basics
Current, voltage, resistance, and power form the foundation. Know Ohm’s Law and Watt’s Law. Understand series and parallel circuits. These ideas appear in almost every journeyman electrician practice test. Know more about NABCEP Certification for Solar Installers
NEC Layout and Use
Knowing how to locate information in the NEC is crucial. The test checks your ability to navigate code sections quickly. Article 250, Chapter 3 wiring methods, conductor sizing, and overcurrent protection are common topics.
Motor and Transformer Knowledge
Expect questions about motor circuits, overload protection, transformer calculations, and nameplate details.
Know more about DEWA Electrical License Guide for Solar Projects in Dubai
Safety Rules and PPE
Electrical safety is a priority. Many questions cover grounding, bonding, shock prevention, and equipment labeling.
Electrical Calculations
Load calculations, box fill, conductor sizing, and voltage drop are frequently tested. Practice these subjects often.
Table: Key NEC Articles Often Tested
| NEC Article | Topic |
|---|---|
| Article 90 | Purpose and scope |
| Article 100 | Definitions |
| Article 110 | Requirements for electrical equipment |
| Article 210 | Branch circuits |
| Article 220 | Load calculations |
| Article 230 | Services |
| Article 240 | Overcurrent protection |
| Article 250 | Grounding and bonding |
| Article 300 | Wiring methods |
| Article 430 | Motors |
| Article 450 | Transformers |
| Article 680 | Pools and fountains |
Use this table as a quick reference while completing the practice test. It will help you understand where each question fits in the NEC.
Know more about Electrical Safety Officer Roles & Responsibilities
Journeyman Electrician Practice Test: 50 Questions
Multiple-Choice Questions (1–50)
- What is the unit of electrical resistance?
A. Ohm
B. Volt
C. Ampere
D. Watt - How many volts are in a standard residential branch circuit in the U.S.?
A. 120
B. 208
C. 240
D. 480 - Which NEC article covers grounding and bonding?
A. 300
B. 250
C. 430
D. 110 - Where are definitions located in the NEC?
A. Article 90
B. Article 100
C. Article 210
D. Article 240 - Ohm’s Law states that voltage equals current multiplied by:
A. Power
B. Resistance
C. Watts
D. Conductance - A GFCI trips at approximately how many milliamps?
A. 10
B. 15
C. 4–6
D. 30 - What size copper equipment grounding conductor is needed for a 100-amp circuit?
A. 14 AWG
B. 12 AWG
C. 8 AWG
D. 10 AWG - Which conductor color is typically used for grounded (neutral) conductors?
A. Black
B. White
C. Green
D. Red - What is the grounding electrode for a metal underground water pipe?
A. Optional
B. Required
C. Prohibited
D. Special use only - What is the maximum ambient temperature allowed for THHN conductor ampacity?
A. 30°C
B. 60°C
C. 75°C
D. 90°C - A 3-horsepower motor at 230V draws how many full-load amps (approx.)?
A. 7
B. 10
C. 17
D. 28 - Which device protects against overcurrent?
A. GFCI
B. Circuit breaker
C. Surge protector
D. Disconnect switch - What is the required burial depth for a PVC conduit with a 120V circuit?
A. 6 in.
B. 12 in.
C. 18 in.
D. 24 in. - What is the formula for power in watts?
A. P = I × R
B. P = V ÷ I
C. P = V × I
D. P = R ÷ V - Which tool measures continuity?
A. Clamp meter
B. Megger
C. Multimeter
D. Phase tester - A 20-amp branch circuit requires what minimum conductor size?
A. 14 AWG
B. 12 AWG
C. 10 AWG
D. 8 AWG - What is the maximum number of 120V receptacles on a 20-amp general circuit (non-residential)?
A. 6
B. 10
C. 13
D. 15 - Box fill for a #12 conductor counts as how many cubic inches?
A. 1.25
B. 1.5
C. 2.25
D. 2.5 - What is used to connect the electrical service to the utility system?
A. Feeder
B. Service drop
C. Branch circuit
D. Load side conductor - A transformer changes:
A. Voltage
B. Frequency
C. Resistance
D. Phase only - How often must a ladder be inspected?
A. Monthly
B. Yearly
C. Before use
D. Weekly - What determines conductor ampacity?
A. Color
B. Temperature rating
C. Voltage
D. Device type - Voltage drop should not exceed:
A. 3%
B. 10%
C. 15%
D. 20% - A 240V circuit uses how many ungrounded conductors?
A. 1
B. 2
C. 3
D. 4 - What is the primary purpose of bonding?
A. Reduce current
B. Ensure continuity
C. Increase voltage
D. Balance loads - A 15-amp lighting circuit uses which conductor size?
A. 16 AWG
B. 14 AWG
C. 12 AWG
D. 10 AWG - NEC Article 430 applies to:
A. Transformers
B. Motors
C. Branch circuits
D. Overcurrent devices - What material is commonly used for grounding rods?
A. Aluminum
B. Copper or galvanized steel
C. Plastic
D. Rubber - A 3-way switch controls:
A. One light from one location
B. Two lights from one location
C. One light from two locations
D. Two lights from two locations - The symbol Ω represents:
A. Voltage
B. Power
C. Resistance
D. Current - Overcurrent devices must be sized at what percentage for motor circuits?
A. 100%
B. 125%
C. 150%
D. 175% - A conductor identified with green insulation is used for:
A. Neutral
B. Hot
C. Grounding
D. Control circuits - Aluminum conductors require:
A. Anti-oxidant compound
B. No coating
C. PVC wrap
D. Separate grounding - A multiwire branch circuit must have:
A. Shared neutral
B. Separate breakers
C. Two neutrals
D. No grounding - What is the smallest size grounding rod allowed?
A. ½ in. × 6 ft
B. ⅝ in. × 8 ft
C. ¾ in. × 4 ft
D. 1 in. × 2 ft - Parallel circuits have:
A. Equal voltage
B. Equal resistance
C. Equal current
D. Equal impedance - What reduces arc flash risk?
A. Larger wire
B. Lower voltage
C. PPE
D. Smaller loads - A 480V system is usually:
A. Single-phase
B. Two-phase
C. Three-phase
D. Split-phase - What is used to test insulation resistance?
A. Multimeter
B. Clamp meter
C. Megger
D. Receptacle tester - A dedicated circuit is required for:
A. Ceiling fan
B. Table lamp
C. Microwave
D. Smoke detector - Service entrance conductors must be sized from:
A. NEC 250
B. NEC 310
C. NEC 430
D. NEC 240 - Motors must have:
A. One disconnect
B. A separate GFCI
C. Two grounding points
D. Two overcurrent devices - NEC 210.52 applies to:
A. Dwelling receptacles
B. Motor circuits
C. Pools
D. Medical buildings - A feeder supplies:
A. Individual loads
B. Multiple branch circuits
C. Only lighting
D. Only receptacles - A neutral is required in:
A. Switch loops
B. Three-way switches
C. Most new installations
D. Motor circuits only - A 30-amp circuit needs what minimum wire size?
A. 14 AWG
B. 12 AWG
C. 10 AWG
D. 8 AWG - A multiwire branch circuit requires breakers to be:
A. Independent
B. Tied together
C. Oversized
D. Undersized - When calculating box fill, each device counts as:
A. 1 conductor
B. 2 conductors
C. 3 conductors
D. 4 conductors - The purpose of a disconnect is to:
A. Increase voltage
B. Provide a means to open a circuit
C. Ground equipment
D. Reduce noise - Conduit fill is calculated from:
A. Chapter 9, Tables 1-4
B. Article 110
C. Article 310
D. Article 406
Answer Key
- 1-A
- 2-A
- 3-B
- 4-B
- 5-B
- 6-C
- 7-D
- 8-B
- 9-B
- 10-D
- 11-C
- 12-B
- 13-C
- 14-C
- 15-C
- 16-B
- 17-C
- 18-D
- 19-B
- 20-A
- 21-C
- 22-B
- 23-A
- 24-B
- 25-B
- 26-B
- 27-B
- 28-B
- 29-C
- 30-C
- 31-D
- 32-C
- 33-A
- 34-A
- 35-B
- 36-A
- 37-C
- 38-C
- 39-C
- 40-C
- 41-B
- 42-A
- 43-A
- 44-B
- 45-C
- 46-C
- 47-B
- 48-B
- 49-B
- 50-A
Follow Us on Social:
Subscribe our Newsletter on Electrical Insights for latest updates from Electrical Engineering Hub
#JourneymanElectrician, #ElectricianExam, #PracticeTest, #ElectricalTraining, #ExamSuccess, #ElectricianTips, #TradeSkills, #JourneymanPrep, #ElectricalCertification, #SkillMastery