Motor Cable Gland Size

|

Importance of Motor Cable Gland Size

Motor cable gland size is a crucial factor in ensuring safe and reliable electrical installations. Choosing the correct gland size helps maintain enclosure integrity, ensures proper cable anchoring, and reduces mechanical strain. The right size supports performance, safety, and compliance with standards. It also prevents ingress of dust, moisture, or gases into motor terminals.

Overview and Function

Understanding the correct motor cable gland size involves knowledge of cable dimensions, gland types, materials, and environmental factors. It also demands compliance with international standards like IEC, NEC, and BS EN.

Motor cable glands are essential components in power distribution systems. They secure the cable entering a motor junction box and prevent cable movement that could damage terminations. They also provide ingress protection and strain relief. When dealing with motors, particularly in industrial environments, gland selection becomes even more critical.

Gland Types and Materials

There are various types of motor cable glands, including brass, stainless steel, and nylon. Each type suits a particular application depending on mechanical strength, chemical resistance, and environmental exposure. However, regardless of the type, gland size must match the cable’s outer diameter for a tight and secure fit.

Sizing Criteria

The motor cable gland size is usually selected based on the cable’s overall diameter, the number of cores, insulation thickness, and whether the cable is armored or unarmored. Manufacturers typically provide sizing charts that help match cables to gland sizes.

Cable glands are standardized in metric (M) or PG (Panzer-Gewinde) threads. For motors, metric sizes are more commonly used in modern installations.

Gland Size Chart

Below is a table showing typical motor cable gland sizes for different cable diameters.

Cable Outer Diameter (mm)Typical Gland Size (Metric)
4 – 8M16
6 – 12M20
11 – 16M25
15 – 21M32
20 – 26M40
27 – 35M50
35 – 43M63
42 – 53M75
Gland Size Chart

Risks of Incorrect Gland Sizing

Choosing the wrong motor cable gland size may lead to ingress problems or loose fittings, causing operational failures or safety risks. If a gland is too small, it may not grip the cable, leading to strain at the terminals. If it’s too large, it will allow contaminants into the enclosure.

Armored vs. Unarmored Cables

Motor cable gland size selection should also consider whether the cable is armored. Armored cable glands, such as CW or E1W types, are designed to grip the armor mechanically. These glands must match both the cable diameter and armor properties.

For example, a 3-core 4 mm² armored cable with an outer diameter of 14 mm would typically require an M20 CW gland. In contrast, a similar unarmored cable may use an M20 plastic or brass compression gland. The difference is in the gripping mechanism and sealing system.

Environmental Considerations

Environmental conditions play a major role in gland selection. Motors in outdoor or hazardous environments require IP-rated glands. IP68-rated glands are ideal for dusty or wet surroundings. Flameproof glands certified under IECEx or ATEX are used in explosive zones.

IP Ratings and Applications

Ingress Protection (IP) levels are defined in IEC 60529. IP68 glands offer complete dust-tight sealing and protection against continuous water immersion. This makes them perfect for outdoor motors or submerged pump applications.

IP RatingDescriptionSuitable For
IP54Dust-protected, splash-resistantIndoor industrial motors
IP65Dust-tight, water jet resistantGeneral outdoor motors
IP66Powerful water jets protectionMarine or washdown environments
IP67Temporary immersion protectionPumps, underground motors
IP68Continuous immersion protectionSubmersible motors, wet pits

Temperature and Material Suitability

Temperature is another factor in choosing the correct motor cable gland size. Gland seals must handle thermal expansion and contraction. High temperatures may degrade rubber seals or plastic bodies. In such cases, metal glands with thermoset elastomeric seals offer better reliability.

Hazardous Area Requirements

For hazardous areas, compliance with IEC 60079 and ATEX Directive 2014/34/EU is essential. Flameproof glands used for motors in Zone 1 or Zone 2 hazardous areas must be Ex d certified. These glands must be installed following manufacturer guidelines and standards.

Torque and Installation

When selecting motor cable gland size, it’s also important to understand torque requirements. Over-tightening may deform the seal or damage the gland, while under-tightening leads to poor sealing. Manufacturers usually provide recommended torque values for each gland size.

Proper installation procedures are key. Before fitting the gland, ensure the cable sheath is clean and dry. Strip the cable carefully to expose inner conductors without damaging insulation. Insert the cable fully into the gland body, then tighten the nut until the seal grips the sheath securely.

Standards and Compliance

Motor cable gland size selection must also comply with electrical codes. The National Electrical Code (NEC) in the US and the British Standards BS 6121 or BS EN 62444 in the UK provide rules for safe gland installation. These standards define minimum requirements for mechanical strength, sealing, and testing.

VFD and EMC Considerations

In industrial automation and drives, motor cable glands must accommodate variable frequency drive (VFD) cables. These cables have thicker insulation and screening. EMC glands are recommended in such cases. They provide proper grounding and shielding continuity.

For example, a shielded motor cable with an OD of 20 mm may use an M32 EMC gland. These glands come with conductive brushes or metallic claws to clamp the screen, reducing electromagnetic interference.

Enclosure Compatibility

Another consideration is enclosure material. Metallic enclosures may need brass or stainless steel glands, while plastic enclosures are compatible with nylon glands. However, metallic glands must be earthed correctly to avoid potential voltage buildup.

Comparison of Gland Materials

MaterialProsCommon Applications
BrassDurable, corrosion-resistantIndustrial motors, general use
Stainless SteelHigh chemical resistanceChemical plants, marine motors
NylonLightweight, low costIndoor motors, control panels
AluminumLightweight, conductivePortable motors, junction boxes

Vibration Resistance in High Power Motors

When working with motors above 30 kW, vibration becomes a factor. Use glands with vibration-proof locking systems like locknuts and sealing washers. Double compression glands are often preferred as they secure both the inner and outer sheaths firmly.

Labeling and Maintenance

Color coding is not standard in motor cable gland sizes, but some industries use color rings or markers to indicate gland functions or zones. Always label motor glands for easy identification and maintenance.

Final Selection Tips

To summarize, motor cable gland size is selected based on cable diameter, gland type, application, environment, and standards. Never guess the size. Always measure cable dimensions and refer to manufacturer datasheets.

Use a digital caliper to measure the outer diameter of the cable accurately. This ensures you pick the correct gland size. Always round up to the nearest fitting size when the OD is between two gland sizes.

To ensure long-term safety and reliability, only use certified cable glands that comply with IEC, UL, or CSA standards. Look for markings like CE, UL, or Ex for compliance.

Finally, record all gland specifications in motor installation documentation. This helps during inspections, maintenance, or upgrades.

Motor cable gland size may seem like a small detail, but it has a huge impact on motor safety and performance. Don’t overlook it. The right gland size ensures a secure, compliant, and long-lasting electrical installation.

References and Standards:

  • IEC 60529: Degrees of protection provided by enclosures (IP Code)
  • IEC 60079-0 / 60079-1: Explosive atmospheres – equipment protection
  • BS EN 62444: Cable glands for electrical installations
  • NEC (NFPA 70): National Electrical Code
  • ATEX Directive 2014/34/EU
  • Manufacturer datasheets: CMP, Hawke, LAPP, Wiska

Subscribe our Newsletter on Electrical Insights to get the latest updates in Electrical Engineering.